PIV / PTV 3D Particle Tracking

by Monocular 4D Plenoptic Technology

Raytrix Light-Field PTV Cameras offer

Completely New Possibilities

With a single Raytrix light field PTV camera you can capture both: 3D particle positions and 3D particle velocities in a volume. The patented micro lens array design used in Raytrix cameras offers an optimal combination of depth-of-field and effective resolution, which makes them the highest resolving light field cameras on the market.

  • Single camera volumetric PTV

    3D particle positions and 3D velocities with a single camera

  • Easy metric calibration

    Cameras can be easily metrically calibrated with the Raytrix software RxLive.

  • Versatile application

    Many different cameras types available including double shot, high speed capture and micro PTV.

Simultaneous Flow and Surface Measurement

Using an R29 PTV

  • Capture flow and surface shape

    The same camera is used to capture the particle flow and the variations of the surface due to the flow.

  • Simple & robust setup

    Only one camera is needed, which largely simplifies the experimental setup.

  • Volumetric Particle Tracking

    Particles are tracked within a volume of 100 x 100 x 60 mm (WxHxD).

Flow
PlayPlay
PlayPause

RxFlow Software

3D Flow Analysis with

  • Analyse flow from double shot or continuous image capture

    RxFlow analyses flow from a single or a sequence of double shots, as well as from continous image captures.

  • Specialized flow analysis from raw image

    The 3D flow is calculated directly from the raw light field images assuming particle images.

  • Direct Visualization

    RxFlow visualizes the data in 3D and can also store it in ParaView file format or for interactive visualization in PowerPoint.

No Compromises

All with one camera

Single Camera

Only a single Raytrix light field camera is needed for volumetric PTV

Metric Calibration

Raytrix cameras can be easily metrically calibrated using the Raytrix software RxLive.

Robust

Camera does not become de-calibrated by shaking or moving it.

High Resolution

Raytrix cameras offer a maximal effective resolution of one quarter of the sensor resolution, which makes them the highest resolving light field cameras on the market.

PTV Analysis Software

Raytrix developed the software RxFlow that analyses the light field raw images to calculate 3D particle positions and 3D velocities.

Precision

In a volume of 63 x 94 x 60 mm the standard deviation is 0.06 mm (0,1%) laterally and 0.24 mm (0.4%) along the optical axis.

Single Camera Volumetric PTV

Learn more about the new possibilities

We are happy to discuss your application idea with you or answer your questions.